Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Cardiovasc Electrophysiol ; 33(5): 1062-1066, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35229370

RESUMO

INTRODUCTION: Although uncommonly encountered, dual atrioventricular nodal non-reentrant tachycardia (DAVNNRT) is a well-described arrhythmia that can manifest in patients with dual atrioventricular nodal pathways physiology. This arrhythmia is characterized on electrocardiogram (ECG) by a single P wave followed by two conducted QRS complexes (so-called "double fire"), and on intracardiac electrograms by a single atrial electrogram followed by two separate His deflections and ventricular electrograms. METHODS/RESULTS: We report a rare case of "triple-fire" atrioventricular non-reentrant tachycardia in which a patient was found to have three distinct atrioventricular nodal pathways and multiple triple fire responses, both on surface ECG and intracardiac electrograms. CONCLUSION: Multiple pathways physiology and it's clinical ramifications are discussed.


Assuntos
Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Nó Atrioventricular/cirurgia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia
2.
Heart Rhythm ; 19(2): 206-216, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34710561

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED) implantation rates as well as the clinical and procedural characteristics and outcomes in patients with known active coronavirus disease 2019 (COVID-19) are unknown. OBJECTIVE: The purpose of this study was to gather information regarding CIED procedures during active COVID-19, performed with personal protective equipment, based on an international survey. METHODS: Fifty-three centers from 13 countries across 4 continents provided information on 166 patients with known active COVID-19 who underwent a CIED procedure. RESULTS: The CIED procedure rate in 133,655 hospitalized COVID-19 patients ranged from 0 to 16.2 per 1000 patients (P <.001). Most devices were implanted due to high-degree/complete atrioventricular block (112 [67.5%]) or sick sinus syndrome (31 [18.7%]). Of the 166 patients in the study survey, the 30-day complication rate was 13.9% and the 180-day mortality rate was 9.6%. One patient had a fatal outcome as a direct result of the procedure. Differences in patient and procedural characteristics and outcomes were found between Europe and North America. An older population (76.6 vs 66 years; P <.001) with a nonsignificant higher complication rate (16.5% vs 7.7%; P = .2) was observed in Europe vs North America, whereas higher rates of critically ill patients (33.3% vs 3.3%; P <.001) and mortality (26.9% vs 5%; P = .002) were observed in North America vs Europe. CONCLUSION: CIED procedure rates during known active COVID-19 disease varied greatly, from 0 to 16.2 per 1000 hospitalized COVID-19 patients worldwide. Patients with active COVID-19 infection who underwent CIED implantation had high complication and mortality rates. Operators should take these risks into consideration before proceeding with CIED implantation in active COVID-19 patients.


Assuntos
Bloqueio Atrioventricular , COVID-19 , Controle de Infecções , Complicações Pós-Operatórias , Implantação de Prótese , SARS-CoV-2/isolamento & purificação , Síndrome do Nó Sinusal , Idoso , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/terapia , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/terapia , Comorbidade , Desfibriladores Implantáveis/estatística & dados numéricos , Feminino , Saúde Global/estatística & dados numéricos , Humanos , Controle de Infecções/instrumentação , Controle de Infecções/métodos , Controle de Infecções/organização & administração , Masculino , Pessoa de Meia-Idade , Mortalidade , Avaliação de Resultados em Cuidados de Saúde , Marca-Passo Artificial/estatística & dados numéricos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/mortalidade , Fatores de Risco , Síndrome do Nó Sinusal/epidemiologia , Síndrome do Nó Sinusal/terapia , Inquéritos e Questionários
4.
Mo Med ; 109(3): 204-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22860288

RESUMO

This article will review background information and data supporting the use of fish oil, folic acid, coenzyme Q, and vitamins C, D, and E in the prevention and/or treatment of coronary artery disease.


Assuntos
Doença da Artéria Coronariana/prevenção & controle , Suplementos Nutricionais , Vitaminas/administração & dosagem , Óleos de Peixe/administração & dosagem , Ácido Fólico/administração & dosagem , Humanos , Ubiquinona/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...